The Fire Protection Services Company You Can Count On

If you’re in the market for fire protection services in Cary NC, look no further than Safeguard Fire Protection Services. Unlike other companies that see their clients as another box to tick off a list, Safeguard takes a more personal approach to our work. We use electronic documentation and perform thorough inspections tailored to your specific needs and the equipment of your business, ensuring that you’re getting the best service possible.

But what really sets Safeguard apart is our dedicated technicians, who take the time to get to know you and your needs. It’s this level of commitment that has earned us the trust of our clients who happily recommend Safeguard to their friends and associates. If you’re looking for a fire protection company that values your safety and your trust, you’re looking for Safeguard.

Give us a call at 984-226-4879 to get started today!

Kitchen Fire Suppression Systems in Cary, NC

Keeping a commercial kitchen safe is no easy feat. With the constant use of open flames and high heat, the chance for a fire outbreak is always present. That’s why partnering with Safeguard is a wise choice. We understand the importance of protecting your property and the people within your premises. That’s why we offer 24/7 services to recharge your kitchen hood fire sprinklers if they are discharged. Our team of experts is dedicated to ensuring your kitchen remains safe and secure at all times, so give us a call and let us handle the rest!

Fire Extinguishers in Cary, NC

At Safeguard, we take fire safety seriously. That’s why we offer thorough and accurate fire extinguisher inspections for all different types of fire extinguishers. We know that each type requires different maintenance, and we’re happy to provide that expertise to ensure your equipment is up to code. But that’s not all we do. We also offer recharge, hydrostatic testing, and installation services so that you can ensure your extinguishers are in the best possible places throughout your building. And don’t forget about training for your staff! We’ll help make sure they are equipped to handle any situation that may arise. At Safeguard, we’re committed to keeping you and your building safe.

Emergency Lighting in Cary, NC

In an emergency, it’s critical that everyone in your building can find the nearest exit. That’s why Safeguard is here to help. Our comprehensive emergency lighting solutions keep you compliant with the fire code and ensure that your building is always prepared for the unexpected. Whether you’re dealing with power outages, natural disasters, or other emergencies, our systems will help guide your employees and customers to safety. With our professional installation and maintenance services, you can trust that your emergency lighting will always be ready when you need it most. Don’t wait until it’s too late – let Safeguard protect your business or historical property today.

Recent Jobs and Reviews in Cary, NC

Our Local Reviews by City

Job Locations and Reviews

Tyler K.
Tyler K. Checked in
Completed comprehensive inspection of kitchen hood fire suppression system including thorough examination of all system components, nozzles, fusible links, and manual pull station. Performed distribution pipe air test to verify system integrity and proper pressure retention throughout the piping network. All components found to be in proper working order with system meeting current fire safety code requirements.
Cary, NC 27511
Tyler K.
Tyler K. Checked in
Completed annual 90-minute load test inspection on all emergency and exit lighting systems throughout the facility. All emergency lights and exit signs were tested under full load conditions to verify proper battery backup operation and illumination levels meet code requirements. Systems performed satisfactorily with all units maintaining adequate lighting for the required 90-minute duration.
Cary, NC 27518
Tyler K.
Tyler K. Checked in
Completed comprehensive inspection of kitchen hood fire suppression system including thorough examination of all system components, nozzles, piping, and actuating mechanisms. Performed distribution pipe air test to verify system integrity and proper pressure distribution throughout the network. All components were found to be in proper working order and the system passed inspection in accordance with NFPA 96 standards.
Cary, NC 27518
Tyler K.
Tyler K. Checked in
Conducted comprehensive inspection of paint booth fire suppression system, verifying proper operation of all detection devices, discharge nozzles, and manual pull stations. Tested system pressure levels, examined piping and connections for leaks or damage, and confirmed adequate chemical agent supply. All components found to be in compliance with NFPA standards and system operational for continued protection of the paint booth facility.
Cary, NC 27518
Jacob S.
Jacob S. Checked in
Completed comprehensive inspection of kitchen hood fire suppression system including thorough examination of all system components, nozzles, piping, manual pull station, and gas/electric shutdown devices. Performed distribution pipe air test to verify system integrity and proper pressure distribution throughout the piping network. All components were found to be in proper working order and system meets current fire safety code requirements.
Cary, NC 27518
Jacob S.
Jacob S. Checked in
Completed comprehensive inspection of kitchen hood fire suppression system, including examination of all nozzles, fusible links, manual pull station, and gas/electrical shut-off controls. Verified proper placement and condition of detection components, tested system actuation mechanisms, and confirmed adequate coverage of cooking equipment and exhaust plenum. Ensured compliance with NFPA 17A standards and documented all findings for regulatory requirements.
Cary, NC 27511
Jacob S.
Jacob S. Checked in
Completed comprehensive inspection of kitchen hood fire suppression system including verification of nozzle placement and orientation, fusible link integrity, manual pull station operation, and system pressure levels. Examined all distribution piping for proper securing and potential obstructions, tested cylinder weight and charge status, and confirmed proper clearances around cooking equipment. Verified compliance with NFPA 96 standards and documented system nameplate information, with all components found to be in proper working order and ready for service.
Cary, NC 27518
Tyler K.
Tyler K. Checked in
Completed comprehensive inspection of kitchen hood fire suppression system including examination of all nozzles, piping, manual pull stations, and fusible links for proper positioning and functionality. Verified system pressure levels, checked tank weight and agent charge, and tested all electrical connections and detection devices. Confirmed system compliance with NFPA 96 standards and documented all findings with system ready for operation.
Cary, NC 27519
Tyler K.
Tyler K. Checked in
Completed comprehensive inspection of kitchen hood fire suppression system including examination of all nozzles, fusible links, manual pull station, and distribution piping for proper positioning and functionality. Verified system pressure levels, checked expiration dates on agent tanks, and tested manual release mechanism to ensure operational readiness. Confirmed all components meet NFPA 17A standards and documented system condition with no deficiencies noted.
Cary, NC 27518
Tyler K.
Tyler K. Checked in
Completed annual emergency and exit light inspection performing 30-second function tests on all units throughout the facility. Verified proper illumination, battery backup operation, and compliance with life safety code requirements. All emergency lighting systems tested and confirmed operational.
Cary, NC 27518
Tyler K.
Tyler K. Checked in
Completed comprehensive kitchen hood fire suppression system inspection including thorough examination of all system components, nozzles, fusible links, and manual pull stations. Performed distribution pipe air test to verify system integrity and ensure proper pressure distribution throughout the piping network. Confirmed all safety mechanisms are functioning correctly and system is in full compliance with fire code requirements.
Cary, NC 27518
Jacob S.
Jacob S. Checked in
Replaced faulty detection line on kitchen hood fire suppression system to restore full operational capability. System was tested and verified to ensure proper detection and activation functionality upon completion of the repair.
Cary, NC 27518
Jacob S.
Jacob S. Checked in
Completed comprehensive kitchen hood fire suppression system repair including full replacement of the detection line. Performed hydrostatic testing on three cylinders and one regulator to ensure proper pressure ratings and system integrity. Replaced three hoses, three bursting disks, and one cartridge to restore the system to full operational status and code compliance.
Cary, NC 27513
Tyler K.
Tyler K. Checked in
Completed annual inspection of all fire extinguishers, verifying pressure levels, physical condition, accessibility, and signage compliance. Performed annual inspection of emergency and exit lighting systems, testing functionality, battery backup operation, and illumination levels to ensure code compliance and life safety readiness.
Cary, NC 27518
Tyler K.
Tyler K. Checked in
Completed annual 30-second push button inspection of all emergency and exit lighting fixtures to verify proper illumination and battery backup functionality in accordance with safety code requirements. All units were tested for adequate light output during simulated power failure conditions and confirmed operational compliance.
Cary, NC 27511
Tyler K.
Tyler K. Checked in
Completed annual inspection of all fire extinguishers on premises, verifying proper pressure levels, checking for physical damage, ensuring accessibility and visibility, and confirming that all units are within their certification dates. Performed visual examination of hoses, nozzles, pins, and tamper seals, and attached new inspection tags documenting compliance with NFPA 10 standards. All fire extinguishers were found to be in serviceable condition and ready for emergency use.
Cary, NC 27511
Jacob S.
Jacob S. Checked in
Serviced paint booth fire suppression system by discharging, inspecting, and recharging one 17-pound ABC dry chemical cylinder that displayed low pressure on its gauge. Rebuilt the cylinder valve per manufacturer specifications, performed leak testing, and returned the unit to full operational service.
Cary, NC 27513
Tyler K.
Tyler K. Checked in
Responded to report of non-compliant fire extinguishers at facility. Identified and replaced two expired extinguishers in the fixture room that had exceeded their service life certification. Reinstalled one extinguisher at the base of the stockroom stairs, ensuring proper mounting height and accessibility per NFPA standards.
Cary, NC 27518
Tyler K.
Tyler K. Checked in
Completed comprehensive inspection of paint booth fire suppression system, verifying all components including discharge nozzles, fusible links, manual pull stations, and pressure gauges were in proper working condition. Tested system activation mechanisms, confirmed adequate agent levels in storage tanks, and ensured all safety signage and operational instructions were clearly visible and compliant with current fire safety standards. All findings documented and system verified as fully operational for continued safe use in painting operations.
Cary, NC 27513
Tyler K.
Tyler K. Checked in
Completed annual testing and inspection of fire extinguishers in accordance with fire marshal requirements. Performed thorough examination of all units, verified proper pressure levels, inspected hoses and nozzles for damage, and confirmed accessibility and signage compliance. Tagged all extinguishers with current inspection dates to maintain code compliance.
Cary, NC 27518
Jacob S.
Jacob S. Checked in
Installed one extinguisher mounting bracket at bay door location. Performed six-year maintenance on one 10lb ABC extinguisher located at back left pole. Completed hydrostatic testing on six 10lb ABC extinguishers positioned at right exit door, back right pole, front right pole, front left pole, men's dressing room, and bay door.
Cary, NC 27519
Tyler K.
Tyler K. Checked in
Annual fire extinguisher and emergency light inspection.
Cary, NC 27511
Tyler K.
Tyler K. Checked in
Completed annual inspection of all fire extinguishers and emergency lighting systems to ensure compliance with safety regulations. Verified proper operation, charge levels, mounting hardware, signage visibility, and documented all equipment conditions. All units were tested and found to be in proper working order with no deficiencies noted.
Cary, NC 27511
Tyler K.
Tyler K. Checked in
Completed comprehensive inspection of kitchen hood fire suppression system, including examination of all nozzles, fusible links, piping connections, and manual pull station for proper operation and compliance. Verified system pressure levels, tested mechanical and electrical components, and confirmed adequate agent supply in cylinders. All components found to be in satisfactory working condition with no deficiencies noted.
Cary, NC 27513
Jacob S.
Jacob S. Checked in
Performed kitchen hood fire suppression system inspection and discovered both automatic detection lines failed due to excessive grease accumulation in conduits and detectors. Replaced complete detection line assemblies for both systems, including all detectors, cable, conduit, fusible links, scissors, and corner pulleys within and between hoods. All components were installed to manufacturer specifications and systems restored to proper operating condition.
Cary, NC 27518
Request Service
servicedetailscustomerreturningschedule
Details Regarding Your Request...
Optional: Drag and drop photos and/or videos:
Max. file size: 4 MB.
Your Contact and Service Location...
*
*
To Serve You Best...
Have we served you in the past?
Yes
No
What Is Convenient For You?
What time of day is best for you?
First Available
Morning
Afternoon

Call For Same Day Service/Emergencies at 984-226-4879 .

Back Next